Sign in →

Test Code FE Iron LAB94

Performing Laboratory

UnityPoint The Finley Hospital

Test Method

Colorimetric; Roche cobas Pro

 

Performance

Testing is performed Monday through Sunday.

Routine orders: Typically completed within 4 hours after the specimen arrives at the testing site.

STAT: Typically completed within 30 minutes after the specimen arrives at the testing site.

Specimen Requirement

  1. Lithium heparin plasma (green) is the specimen of choice. 0.5mL
  2. Serum (red/gold) is also an acceptable sample type.
  3. Separate serum or plasma from the clot or cells within 1 hour.
  4. Iron specimens are stable for 7 days at 20-25°C, 3 weeks at 4-8°C, and 1 year at -20°C.

Useful For

Iron (non-heme) measurements are used in the diagnosis and treatment of diseases such as iron deficiency anemia, hemochromatosis (a disease associated with widespread deposit in the tissue of the two iron-containing pigments, hemosiderin and hemofuscin, and characterized by pigmentation of the skin), and chronic renal disease. Iron determinations are performed for the diagnosis and monitoring of microcytic anemia (e.g. due to iron metabolism disorders and hemoglobinopathy), macrocytic anemia (e.g. due to vitamin B12 deficiency, folic acid deficiency and drug‑induced metabolic disorders of unknown origin) as well as normocytic anemias such as renal anemia (erythropoetin deficiency), hemolytic anemia, hemoglobinopathy, bone marrow disease and toxic bone marrow damage.

Reference Values

  1. Male: 61-157 μg/dL
  2. Female: 37-145 μg/dL

    TIBC: 255 - 479 μg/dL
    %Saturation: 20 - 50%

CPT Code Information

83540: Chemistry: Iron

LOINC Code Information

2498-4  Iron [Mass/Volume] In Serum Or Plasma