Test Code SYCAMR Allergen Sycamore, American IgE
Performing Laboratory
St. Luke's Hospital Cedar Rapids
Specimen Requirements
Serum
Container/Tube: Serum gel tube or plain, red-top tube
Specimen: 40 uL for each allergen in addition to 200 uL for dead space serum
Note: Label specimen appropriately (serum).
Minimum Requirements: 550 uL for component testing
Specimen Type |
Temperature |
Time |
Serum |
Refrigerated (preferred) |
7 days |
Frozen |
Indefinite |
Reference Values
SIgE kUA/L |
Interpretation |
|
<0.10 |
None Detected | |
0.10 - 0.69 |
Low | |
0.70 - 3.49 |
Moderate | |
3.50 - 17.4 |
High | |
17.5 - >100.0 |
Very High |
Day(s) Test Set Up
Monday - Friday
Methodology
Fluorescence Enzyme Immunoassay (FEIA)
Test Classification and CPT Coding
86003
Useful For
Testing for IgE antibodies may be useful to establish the diagnosis of an allergic disease and to define the allergens responsible for eliciting signs and symptoms.
Report Available
2-4 days upon receipt