Test Code SFPCR CSF FILM ARRAY PCR PANEL LAB6330
Test Method
Multiplex Polymerase Chain Reaction (PCR); FilmArray ME
Panel
Performance
Testing is performed Monday through Sunday.
Typically completed within 3 hours after the specimen arrives at
the testing site.
Specimen Requirement
Collect in CSF container. A minimum volume of 1 mL CSF required
in addition to volume required for other tests run on the same
specimen. Transport to the laboratory immediately.
Useful For
The FilmArray meningitis/encephalitis panel is a multiplex PCR
test capable of qualitatively detecting DNA or RNA of 14 pathogens
(bacteria and viruses) from human cerebrospinal fluid.
The panel is used to diagnose infection caused by Escherichia coli,
Haemophilus influenzae, Listeria monocytogenes, Neisseria
meningitidis, Streptococcus agalactiae, Streptococcus pneumoniae,
Cytomegalovirus (CMV), Enterovirus (including Coxsackie virus A/B,
Echovirus, and Enterovirus, including EV-D68, EV-D70, and EV-D71),
Human herpesvirus 6 (HHV-6), Herpes simplex virus 1 (HSV-1), Herpes
simplex virus 2 (HSV-2), Human parechovirus, Varicella zoster
virus, and Cryptococcus neoformans/gattii.
Use is discouraged in these situations:
- Suspected neurosurgical infection-this assay will not detect
the most common pathogens. - In patients with presumed Lyme neuroborreliosis.
- In patients whose clinical scenario suggests an alternative
infectious diagnosis-this may be used in combination with other
assays. - Do not use alone when suspicion for bacterial
infection is high-cultures need to be performed for susceptibility
testing. - Do not use CSF obtained from ports, shunts, or any LP completed
for reasons other than to R/O meningitis/encephalitis.
CPT Code Information
87483
Additional Specimen Collection Information
Collection Instructions:
- Minimum volume: 0.2 mL
- Hemolysis: NA
- Lipemia: NA
- Icterus: NA
- Storage: Specimens should be tested as soon as possible, though
they may be stored for up to one day at room temperature
(18-30ºC), or refrigerated (2-8ºC) for up to seven
days.
LOINC
In Process
Reference Value
Not Detected