Test Code HEPABT Hepatitis B Virus Surface Antibody Monitor, Post-Transplant, Serum
Additional Codes
MAYO: HBABT
EPIC: LAB2497
Reporting Name
HBs Ab Monitor, Post-transplant, SUseful For
Monitoring serum hepatitis B virus surface antibody levels during intravenous or intramuscular hepatitis B immune globulin therapy to prevent hepatitis B virus reinfection in liver transplant recipients with known previous chronic hepatitis B
Testing Algorithm
For more information see HBV Infection-Monitoring Before and After Liver Transplantation.
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
Serum SSTNecessary Information
Date of collection is required.
Specimen Required
Patient Preparation: For 24 hours before specimen collection, patient should not take multivitamins or dietary supplements (eg, hair, skin, and nail supplements) containing biotin (vitamin B7).
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Serum gel (red-top tubes are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 0.7 mL
Collection Instructions:
1. Centrifuge blood collection tube per manufacturer's instructions (eg, centrifuge and aliquot within 2 hours of collection for BD Vacutainer tubes).
2. Aliquot serum into plastic vial.
Specimen Minimum Volume
0.6 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum SST | Frozen (preferred) | 90 days | |
Refrigerated | 6 days | ||
Ambient | 7 hours |
Special Instructions
Reference Values
Not applicable
Day(s) Performed
Monday through Saturday
Test Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
86317
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
HBABT | HBs Ab Monitor, Post-transplant, S | 5193-8 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
HBABT | HBs Ab Monitor, Post-transplant, S | 5193-8 |
Report Available
Same day/1 to 3 daysReject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | Reject |
Heat-inactivated specimen | Reject |
Method Name
Electrochemiluminescence Immunoassay (ECLIA)
Forms
If not ordering electronically, complete, print, and send 1 of the following: